Resultant and centroid of beam loads

Use this workflow after the loads share one unit system. The question is different from normalization: where does one equivalent force act, and when does that question have no answer?

1. Choose the origin and the positive sense

Measure every station from the same origin, usually the left end. Keep one sign for a given direction. Opposite sense is a negative force, not a second axis. Write applied moments in their own column. A moment is not a force, so it does not enter the force total.

2. Replace each uniform load by its area

For a uniform intensity w on an interval of length L, the equivalent force is R = wL and it acts at the midpoint. That is the centroid of a rectangle. A point force is already its own resultant and acts at its station.

3. Sum forces and first moments

Net force R = ΣFi. First moment about the origin M₁ = Σ(Fi xi). If R is not zero, the resultant station is x̄ = M₁ / R. Check the identity R x̄ = M₁ before you copy the station into another calculation.

If R is zero, stop. Equal and opposite forces are a couple. There is no single station that represents them as one sliding force. Report the first moment and the applied-moment total, and leave the station undefined.

Worked numerical example

Two forces in the same sense: 10 kN at 2 m and 20 kN at 5 m. R = 30 kN. M₁ = 10×2 + 20×5 = 120 kN·m. x̄ = 120/30 = 4 m. The identity 30×4 = 120 holds.

Add a uniform 4 kN/m from 1 m to 3 m. Equivalent force = 4×2 = 8 kN at 2 m. Combined with the two point forces, R = 38 kN and M₁ = 120 + 8×2 = 136 kN·m, so x̄ = 136/38 = 3.578947 m, to the displayed precision.

A 6 kN·m applied moment changes the moment column by 6 kN·m and leaves R and x̄ where they were.

Cancelling case: 10 kN at 0 m and −10 kN at 4 m. R = 0. M₁ = 0×10 + 4×(−10) = −40 kN·m. The station is undefined. Do not divide −40 by zero.

Limitations

  • The forces are treated as parallel. An axial component needs the equilibrium checker, not this centroid.
  • Only a uniform distribution is reduced here. A triangular load has its centroid at one third of the base, which this page does not compute.
  • The resultant is a statics replacement of the loads. It is not a support reaction and not a code check.

References

  • Hibbeler, R. C., Engineering Mechanics: Statics, Pearson. Parallel-force resultants and the centroid of a distributed load. The project source registry does not pin an edition or year for the related structural-analysis bibliography.
  • Beer, F. P., Johnston, E. R., and Mazurek, D. F., Vector Mechanics for Engineers: Statics, McGraw-Hill. Equivalent force of a distributed load equals the area under the load diagram and acts through the centroid.
  • Hibbeler, R. C., Structural Analysis, Pearson, as recorded in this site's source registry for beam equilibrium identities. Edition and year are unset in that registry.

Open the resultant calculator · Previous: normalize units · Next: check equilibrium